GX-C
Multi-channel accident prevention and safety light barrier systems with muting
 | | - Safety category 4
- For Ex- and standard ranges
- Central monitoring
- Permanent self-monitoring
- Pollution indicator
- Operating Instructions GX-C
|
The multi-channel accident prevention system GX-C is used for operator protection in dangerous areas and has been approved according to safety category 4.
A system consists of 1 controller and, depending on the stage of expansion, of 2 to 6 transmitters / receiver light barriers.
Specification:
Type | GX-C | Number of light barriers | max. 6 Light barriers | Range | 0,1 - 10m bzw. 0,1 - 20m | Supply voltage | Controller 24V DC Light barriers 12V DC from controller | Current consumption | 470 mA (incl. 6 light barriers) | Reaction time | 30 ms | >adm. ambient temperature | -10°C....+50°C | Enclosure rating / light barrier | Controller IP 20 Light barrier IP 65 to DIN 40050 | Safety output connected to safety system | 2xNO / 2xNC | 2xNO / 2xNC | 1xNPN (open collector) | Accessories | 2 Nuts or 2 clamps M30 |

|
|